380v 4kw 5hp variable frequency drive vector control inverter VFD
VFD500 features and technical data sheet:
1, With inside EMC C3 filter and building-block design for IO extension card and different kinds of PG card
2, Top performance in our industry which represent in torque in less than 1hz 0.5hz 0.25hz 0.1hz and 0hz
it can compare with any domestic chinese brand for output torque.
3, Smooth running and stability, support optional LCD keypad and dual display keypad. support PC tools.
4, Support modbus485, canopen, profinet communciation.
5, Low noise on motor and fast response for 0.1S acceleration and deceleration without dead zone
6, Reverse and forward free switching
7, Sleeping function and energy saving function as well as in built PLC programming
8, Tension control and torque mode control
9, Support two group motor parameters which can realize two motor switching control
Item | Specifiation |
Input | Inuput Voltage | 1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V |
| Allowed Voltage fluctuation range | -15%~10% |
| Input frequency | 50Hz / 60Hz,fluctuation less than 5% |
Output | Output Voltage | 3phase:0~input voltage |
| Overload capacity | General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current |
Control | Control mode | V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) |
| Operating mode | Speed control,Torque control(SVC and VC) |
| Speed range | 1:100 (V/f) 1:200( SVC) 1:1000 (VC) |
| Speed control accuracy | ±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC) |
| Speed response | 5Hz(V/f) 20Hz(SVC) 50Hz(VC) |
| frequency range | 0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) |
| Input frequency resolution | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.1% |
| Startup torque | 150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 200%/0Hz(VC) |
| Torque control accuracy | SVC:within 5Hz10%,above 5Hz5% VC:3.0% |
| V/f curve | V / f curve type: straight line, multipoint, power function, V / f separation; Torque boost support: Automatic torque boost (factory setting), manual torque boost |
| Frequency giving ramp | Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s |
| DC bus voltage control | Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault; Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip; VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault |
| Carrier frequency | 1kHz~12kHz(Varies depending on the type) |
| Startup method | Direct start (can be superimposed DC brake); speed tracking start |
Replace famous brands vfd in general application.
Sleeping function
41 Group Sleeping function |
P41.00 | Sleep mode and wake up selection | Unit’s digit: sleep mode selection 0:no sleep function 1:sleep by frequency 2:AI1 sleep (AI1 as pressure feedback) 3:AI2 sleep(AI2 as pressure feedback) 4:AI3 sleep (AI3 as pressure feedback) 3:AI4 sleep(AI4 as pressure feedback) Ten’s digit :wake up mode selection 0:wake up by frequency 1:AI1 wake up (AI1 as pressure feedback) 2:AI2 wake up (AI2 as pressure feedback) 3:AI3 wake up (AI3 as pressure feedback) 4:AI4 wake up (AI4 as pressure feedback) Hundred’s digit:Sleep wake direction selection 0: positive direction Sleep source (AI1 ~ AI4) > P41.03, inverter will sleep Wake-up source (AI1 ~ AI4) < P41.04, the inverter will wake up 1: reverse direction Sleep source (AI1 ~ AI4) < P41.03, inverter sleep Wake-up source (AI1 ~ AI4) > P41.04, the inverter wakes up. - When the sleep source and wakeup source are the same, please pay attention to the size relationship of P41.03 and P41.04. If the parameter setting is unreasonable, when the wake-up condition is selected, even if the sleep condition is established, the sleep state cannot be entered, and special attention is required when using.
| 010 | ☆ |
P41.01 | Sleep setting value by frequency | 0.00Hz~600HZ,It will sleep if value is less than this value | 0.00Hz | ☆ |
P41.02 | Wake up threshold by frequency | 0.00hz~600.00hz, ,It will wake up if value is bigger than this value | 0.00Hz | ☆ |
When selecting frequency sleep and frequency wake-up, it must be set by P41.01 < P41.02. When the frequency source is PID setting, and the frequency wake-up must be set to PID shutdown operation: P40.39 = 1. |
P41.03 | Sleep setting value by pressure | 0~100.0% | 0.0% | ☆ |
P41.04 | Wake up threshold by pressure | 0.~100.0% | 0.0% | ☆ |
P41.05 | Sleep delay time | 0.0s~6000.0s | 0.0s | ☆ |
P41.06 | Wake up delay up | 0.0s~6000.0s | 0.0s | ☆ |
P41.07 | Sleep decelerating time | Setting value decide by P03.16 P03.16 = 2, 0.00~600.00s; P03.16 = 1, 0.0s~6000.0s; P03.16 = 0, 0s~60000s P41.07 set to 0,sleeping stop mode to free coast. | 0.00s | ☆ |