Shenzhen Veikong Electric Co., Ltd.

Shenzhen Veikong Electric Co., Ltd.

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Solar Water Pump Controller /

Air Cooling and IP20 Protection Degree in Solar Water Pump Controller

Contact Now
Shenzhen Veikong Electric Co., Ltd.
Visit Website
City:shenzhen
Country/Region:china
Contact Person:MrTerry
Contact Now

Air Cooling and IP20 Protection Degree in Solar Water Pump Controller

Ask Latest Price
Video Channel
Brand Name :VEIKONG
Model Number :VFD500-PV
Certification :CE
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :L/C, T/T, Western Union
Supply Ability :15000pcs per Month
Delivery Time :3 days, depend on the order quantity
Packaging Details :the power less than 45kw use Carton, starting from 45kw use Wooden case
Product Name :11KW solar pump controller
Current :25A/32A
Output type :single phase or three Phase
Voltage :220v/380v
Output power :11kw/15kw
Warranty :18 monthes
Application :Submersible pump
Usage :Water system
OME :Supported
Color :Dark blue
MPPT efficiency :99.9999%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Solar water pump controller inverter 11kw 15kw for solar pump system

Electrical Specifications and Power degree

220V 380V
Max input DC voltage 450V 810V
DC voltage range 150~450VDC 300~810VDC
Normal working DC voltage 260V-400V 400V-650V
Recommended input mppt voltage 330V 550V
MPPT efficiency >99%
Rated output voltage 1/3-phase 220VAC 3-phase 380-480VAC
Output frequency range 50/60Hz
Max efficiency of the machine 99%
Power range 220v 0.75kw to 75kw, 380v 1.5kw-160kw
Cooling method Air cooling
Protection degree IP20/IP65
Altitude Below 1000m; above 1% for every additional 100m.
Standard CE/ROHS

Noted: We suggest solar panel power should be 1.3-1.4 times higher than solar pump power ,

And solar pump inverter power should be higher level than solar pump.

When solar pump distance to inverter higher than 100m,

It should be equipped with Output reactor or higher level power inverter.

For Solar panel,total VOC less than Maximum DC voltage of inverter and Solar panel vmp is recommend

530V for 380V pump and 305V for 220V pump.

VEIKONG VFD500-PV solar pump inverter benefits:

Solar pumping system including solar pump inverter, solar panels, solar water pump.

When sunshine is good enough, it can convert dc from solar panels to ac, using ac to drive solar water pump to get water from the lakes, well, rivers other places where having water. When sunshine is not strong enough, if there is grid power (or generator) in installation site, the users can use grid power or generator to supply ac power to drive the solar pump inverter to get the water from water sources as well.

VEIKONG VFD500-PV series solar pump inverter also has hybrid function, it can connect with grid power (or generator) and solar panels at the same time. It is available for users if they want to operate the solar pump system 24 hours continually.

In General, solar pump inverter and solar pumping system have the following benefits:

  • No need for batteries, longer lifetime
  • No need human to operate when need water, it can be operated automatically when sun comes, it starts, when sunshine is weak, it stops.
  • High cost-effective, with good ROI (return on investment)
  • Can be friendly and widely used where need water, without grid power limitation
  • Support LCD keypad, easy to operate
Product Application
Air Cooling and IP20 Protection Degree in Solar Water Pump Controller

Air Cooling and IP20 Protection Degree in Solar Water Pump ControllerAir Cooling and IP20 Protection Degree in Solar Water Pump Controller

FAQ
1. How to achieve Automatic start after stop?
If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
2. How to design solar PV water pump system?
Key point: the rated VOC and VMP and power of the PV Array need to match the input range of
the inverter. If needed, we will provide technical support online.
3. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
4. How to set minimum frequency ( for example) 30hz and maximum 50HZ
Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07
5. If pump is 60HZ frequency, how to set max frequency?
Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single
phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32

6. How to make the water pump system work without sunshine?

Usually, solar PV water pump system can meet the needs of pumping water.
If there is no sunshine, the system will not work. But out inverter could also support AC input. So, connect the power grid or diesel power generation to the inverter, the pumping system will work. If necessary, keep switch and interface locations during the system design

7. How to check and solve basic problem of inverter trips and error
a:Check the total vmp and voc of solar panels ,solar panel technical data
b:Check motor pump power and rated current
c: Check the distance between motor and inverter
d: Check trip record r25.00 r25.01 25.02 25.03 r26.00 r26.01 r26.02 r26.03
e: Check troubleshooting fault and find relevant solutions
f : Check if motor insulation has been damaged or motor is blocked

Inquiry Cart 0