5.5kw 7.5kw 11kw 3 Phase Solar Pump Inverter For AC Submerged Pump
MPPT 99% Solar pump inverter 220v 2.2kw 3hp inverter for ac submerged pump
Electrical Specifications and Power degree
| 220V | 380V |
Max input DC voltage | 450V | 810V |
DC voltage range | 150~450VDC | 300~810VDC |
Normal working DC voltage | 260V-400V | 400V-650V |
Recommended input mppt voltage | 330V | 550V |
MPPT efficiency | >99% |
Rated output voltage | 1/3-phase 220VAC | 3-phase 380-480VAC |
Output frequency range | 50/60Hz |
Max efficiency of the machine | 99% |
Power range | 220v 0.75kw to 75kw, 380v 1.5kw-160kw |
Cooling method | Air cooling |
Protection degree | IP20/IP65 |
Altitude | Below 1000m; above 1% for every additional 100m. |
Standard | CE/ROHS |
Noted: We suggest solar panel power should be 1.3-1.4 times higher than solar pump power ,
And solar pump inverter power should be higher level than solar pump.
When solar pump distance to inverter higher than 100m,
It should be equipped with Output reactor or higher level power inverter.
For Solar panel,total VOC less than Maximum DC voltage of inverter and Solar panel vmp is recommend
530V for 380V pump and 305V for 220V pump.
The solar pump inverter is the most important equipment in the photovoltaic water pumping system and the soul of the system. Electrical energy from photovoltaic solar panels to drive AC motor water pumps.
Solar pump inverter that switches the DC power supply from the solar panels to the AC power needed to control the pump. With the solar inverter, pumps can adapt to solar energy sources rather than traditional power supplies or generators. Solar pumping system is a series-parallel absorb sunlight radiation energy through solar panels and convert it into AC power by inverter to drive centrifugal pump, irrigation pump, axial flow pump, mixed-flow pump of deep well water pump system.
According to the change of intensity of sunlight, solar pump inverter system adjusts output frequency in real time, output power close to the sun cell array maximum power.
Veikong solar pump drive can help and bring you more water and more green world
1. If pump is 60HZ frequency, how to set max frequency?
Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single
phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32
2. How to make the water pump system work without sunshine?
Usually, solar PV water pump system can meet the needs of pumping water.
If there is no sunshine, the system will not work. But out inverter could also support AC input. So, connect the power grid or diesel power generation to the inverter, the pumping system will work. If necessary, keep switch and interface locations during the system design
3. How to check and solve basic problem of inverter trips and error
a:Check the total vmp and voc of solar panels ,solar panel technical data
b:Check motor pump power and rated current
c: Check the distance between motor and inverter
d: Check trip record r25.00 r25.01 25.02 25.03 r26.00 r26.01 r26.02 r26.03
e: Check troubleshooting fault and find relevant solutions
f : Check if motor insulation has been damaged or motor is blocked