7.5kw 11kw 15kw PMSM Inverter VFD For PMSM Synchronous Motor
Vfd For PMSM Motor Synchronous Motor ac drive 7.5kw 11kw 15kw
VEIKONG hot selling VFD
|
| |
Control | Control mode | V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) |
Operating mode | Speed control,Torque control(SVC and VC) | |
Speed range | 1:100 (V/f) 1:200( SVC) 1:1000 (VC) | |
Speed control accuracy | ±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC) | |
Speed response | 5Hz(V/f) 20Hz(SVC) 50Hz(VC) | |
frequency range | 0.00~2000.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) | |
Input frequency resolution | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.1% | |
Startup torque | 150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 200%/0Hz(VC) | |
Torque control accuracy | SVC:within 5Hz10%,above 5Hz5% VC:3.0% | |
V/f curve | V / f curve type: straight line, multipoint, power function, V / f separation; Torque boost support: Automatic torque boost (factory setting), manual torque boost | |
Frequency giving ramp | Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s | |
DC bus voltage control | Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;
Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure
VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip; VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault | |
Carrier frequency | 1kHz~12kHz(Varies depending on the type) | |
Startup method | Direct start (can be superimposed DC brake); speed tracking start | |
Stop method | Deceleration stop (can be superimposed DC braking); free to stop | |
Maincontrol function | Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN | |
|
|
|
Product series instruction:
VEIKONG VFD application:
VEIKONG VFD replace famous brands
17 group synchronous motor control | ||||
P17.00 | Initial position identification mode | 0:Pulse testing 1: High frequency injection | 1 | ★ |
P17.01 | Initial position identification current | 50%~180% | 100% | ★ |
P17.03 | Low speed zone definition | 0.1% ~ 60.0% | 10.0% | ★ |
P17.07 | High frequency injection amplitude | 5% ~ 50.0% For the amplitude of high-frequency signal injection, the larger the set value, the higher the accuracy of position identification, but the greater the noise of the motor. The set value should be as small as possible when the accuracy meets the requirements. | 20.0% | ☆ |
P17.11 | Operation mode in low speed in SVC | 0: normal way 1: High frequency injection operation | 0 | ★ |
P17.12 | No load current in low speed in SVC | 0.0% ~ 100.0% | 20% | ☆ |
P17.13 | No load current in high speed in SVC | 0.0% ~ 50.0% | 2.0% | ☆ |
P17.18 | MTPA control | 0:disable 1:enable MTPA is the maximum torque current ratio control. Enabling MTPA can reduce the motor current when SVC and VC are running under load. | 0 | ☆ |
P17.19 | MTPA control adjust time | The smaller the set value, the faster the MTPA will act, it will cause current oscillation if set value too small | 0.500 | ☆ |