Shenzhen Veikong Electric Co., Ltd.

Shenzhen Veikong Electric Co., Ltd.

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Solar Water Pump Controller /

0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%

Contact Now
Shenzhen Veikong Electric Co., Ltd.
Visit Website
City:shenzhen
Country/Region:china
Contact Person:MrTerry
Contact Now

0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%

Ask Latest Price
Video Channel
Brand Name :VEIKONG
Model Number :VFD500-PV
Certification :CE
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :L/C, T/T, Western Union
Supply Ability :15000pcs per Month
Delivery Time :depend on the order quantity
Packaging Details :the power less than 45kw use Carton, starting from 45kw use Wooden case
Product Name :solar pump inverter
Voltage :380v/220v
Frequency :50hz/60hz
Warranty :18 months
Efficiency :99%
IP level :IP20/IP65
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%

160kw solar pump inverter with MPPT 99% PID controller solar vfd

Why chose VEIKONG?

1. Infineon brand IGBT/Fuji IGBT, enduree temperature 175°C
2. Two-lines LED keypad/LCD kaypad
3. Fan: 70 000 hours using life
4. Capacitor: 50 000 hours using life
5. Input phase lacking protection
6. Output short circuit protection
7. Overvoltage protection
9. 10 000-15 000pcs per month production ability
10. 500pcs stock below 90KW
11. CE ISO certification, TUV SGS authority
12. Strong RD department, can update software

Key Features:

1, Support single phase/three phase 220V, and three phase 380V solar water pump inverter, power from 0.75kW to 160KW

2, Simply connect the photovoltaic panel to the inverter, no need to set any parameters.

3, It has protection functions such as overvoltage protection, overcurrent protection, dry runing protection, full water protection.


4, Advanced MPPT algorithm. Ensure solar power tracking efficiency can reach 99.99%

5, Supports optional GPRS module, which can realize remote monitoring function of computer webpage and mobile APP

6, Support PV DC input and grid AC input at same time, which can meet 24 hours of no care work

7, Support LCD keypad, it is easier to monitor system situation.


Electrical Specifications and Power degree

220V

380V

Max input DC voltage

450V

810V

DC voltage range

150~450VDC

300~810VDC

Normal working DC voltage

260V-400V

400V-650V

Recommended input mppt voltage

330V

550V

MPPT efficiency

>99%

Rated output voltage

1/3-phase 220VAC

3-phase 380-480VAC

Output frequency range

50/60Hz

Max efficiency of the machine

99%

Ambient temperature range

-10 °C~50 °C, derating if the temperature is above 40 °C

Cooling method

Air cooling

Protection degree

IP20/IP21

Altitude

Below 1000m; above 1% for every additional 100m.

Standard

CE/ROHS



Accessories:

1. GPRS (support 2g/3g/4g internet)

0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%

2. LCD keypad


0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%


3. Output Reactor

0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%


VFD500-PV solar pump inverter picture:
0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%

Connect wire diagram

0.75kW To 160KW VFD Solar Water Pump Controller With MPPT 99%

Techincal Parameters:

1. Wake up and sleep function parameters:

P47.05 Light detection threshold If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop 0Hz
P47.06 Light detection time See P47.05 for explanation. 60s
P47.07 Light weak wake up time After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues. 600s

2. Dry runing protection function parameters:

P24.12 Dry run/Unload protection option

0: No offload detection is performed;

1: Enable dry run detection

1
P24.13 Dry run/Unload detection level

0.0 to 200.0%

The percentage of motor rated current.

0.0%
P24.14 Dry run Unload detection time 0.000s~60.000s 30.000s
P24.15 Unload detection offset frequency

0.00Hz~Fmax

Detection frequency=Fmax-P24.15

5.00Hz
P24.16 Reset time of dry run protection 0.0~6000.0 240.0s
P23.21 Dry run detection mode

0000:Coast stop

1000:Fast stop

3000:Continue to run

0000

FAQ
1. How to achieve Automatic start after stop?
If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
2. How to design solar PV water pump system?
Key point: the rated VOC and VMP and power of the PV Array need to match the input range of
the inverter. If needed, we will provide technical support online.
3. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
4. How to set minimum frequency ( for example) 30hz and maximum 50HZ
Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07


Inquiry Cart 0