Single Phase Solar Pump Inverter 220v 380v 5.5kw 7.5kw 7.5hp 10hp
Features:
1, Comprehensive voltage level and power range
Support single phase/three phase 220V, and three phase 380V solar water pump inverter, power from 0.75kW to 160KW
2, Easy to use
Simply connect the photovoltaic panel to the inverter, no need to set any parameters,
and the PV pump can be automatically started after power-on
3, Multiple protection measures
It has protection functions such as PV over-voltage protection, PV polarity reverse connection alarm, over-temperature automatic derating, etc., which can effectively extend the life of the product
4, Advanced MPPT algorithm
Ensure solar power tracking efficiency can reach 99.99%
Electrical Specifications and Power degree
220V | 380V | |
Max input DC voltage | 450V | 810V |
DC voltage range | 150~450VDC | 300~810VDC |
Normal working DC voltage | 260V-400V | 400V-650V |
Recommended input mppt voltage | 330V | 550V |
MPPT efficiency | >99% | |
Rated output voltage | 1/3-phase 220VAC | 3-phase 380-480VAC |
Output frequency range | 50/60Hz | |
Max efficiency of the machine | 99% | |
Power range | 220v 0.75kw to 75kw, 380v 1.5kw-160kw | |
Cooling method | Air cooling | |
Protection degree | IP20/IP65 | |
Altitude | Below 1000m; above 1% for every additional 100m. | |
Standard | CE/ROHS |
For 220V single phase motor connection
1: Single phase asynchronous motor wiring method (without starting capacitor):
Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;
Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.
First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ
For 220V single phase motor connection
2:Single-phase asynchronous motor wiring method (with capacitor)
Notice1:First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=21 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ