Add to Cart
Solar pump inverter 380v 2.2kw 4kw with LCD keypad for irrigation system
VEIKONG is solar pump inverter manufacturer, supplier, export.
Product Details and Features:
VFD500-PV Seires High Performance Solar Pump Inverter
Power range: 0.75~75kw 220V
0.75~160kw 380V
1. MPPT with 99% high efficiency
2. Driving for AC induction motor or PMSM
3. GPRS remote monitoring and control
4. Long service life working and long warranty
5. Maximum DC power input: 450VDC for 220AC output /810VDC for 380V AC output
6. Easy install and operation, no need set parameters
7. Optional LCD keypad, no need use manual
8. A variety of protection, drying runing protection, water fulling protection, overvoltage protection, overcurrent protection
9. Built in PID function, when MPPT control, PID is also enable.
10. Connect DC and AC power, inverter can work 24 hours.
PV input | |
Maxiumum input DC voltage | 400V DC |
Recommended MPPT voltage range | 250~350V DC |
Recommended input Operation Voltage | 310V DC |
Grid or backup generator input | |
Input voltage | Single phase 220V(-15%~30%) |
Output Specification | |
Rated output voltage | 3PH 220V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
380V Solar Pumping Inverter | |
Input Specification | |
PV input | |
Maxiumum input DC voltage | 800V DC |
Recommended MPPT voltage range | 450~650V DC |
Recommended input Operation voltage | 540V DC |
Grid or backup generator input | |
Input voltage | Three phase 380V(-15%~30%) |
Output specification | |
Rated ouput voltage | 3PH 380V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
Protection | |
Built-in Protection | Lighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc. |
Product Application
For 220V single phase motor connection
1: Single phase asynchronous motor wiring method (without starting capacitor):
Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;
Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.
First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=00031 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ
For 220V single phase motor connection
2:Single-phase asynchronous motor wiring method (with capacitor)
Notice1:First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=00021 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ