Auto Tuning Variable Frequency Inverters Big Torque In Low Frequency And Fast Response
1. VFD500 high performance variable frequency inverter product function and features
1) Deceleration over excitation function. Accurate thermal simulation platform software ensures the reliability of thermal simulation.
2) VPowerful internal logic. Built-in up to 6 sets of delay functions, a wide variety of input sources, the output can be used as a variety of other built-in module inputs. Support some complex algorithm.
3) Rich expansion function. Standard ModbusRTU communication function, support for fieldbus such as Profibus-DP, CanOpen, etc. Supports incremental encoders and resolvers, where incremental encoders are compatible with differential encoders and open collector encoders. Support for IO expansion.
2. Veikong VFD data sheet compare with other products
Other famous brand in China | Veikong | ||
Performance | Overload Capability | G Type: 150% of rated current:1 minute P Type: 120% of rated current: 1 minute 180% of rated current:10 seconds 200% of rated current:1 second | General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current Heavy load overload capability: 110% rated current for long-term stable operation 150% rated current for 1 minute 180% rated current 10s |
Control Mode | SVPWM, SVC | V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) | |
Speed Control Range | Asynchronous motor 1:200(SVC) | 1:100 (V/f) 1:200( SVC) 1:1000 (VC) | |
Starting Torque | Asynchronous motor: 0.5Hz/150%(SVC) | 150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 200%/0Hz(VC) | |
Torque control accuracy | ±0.2%(SVC) | SVC:within 5Hz10%,above 5Hz5% VC:3.0% | |
Frequency Range | Standard:0~400Hz;(380V Goodrive310 special inverters for medium-frequency:0~3200Hz) | 0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) |
3. Veikong VFD500 series wide applications in different industries
4. Veikong product brochure and user manual download center
VEIKONG VFD500 high performance vector and torque ...
veikong catalog latest.pdf
5. Motor Wiring
◆ It is forbidden to short circuit or ground the inverter output terminal, otherwise the internal components of the inverter will be damaged.
◆ Avoid short circuit the output cables or with the inverter enclosure, otherwise there exists the danger of electric shock.
◆ It is forbidden to connect the output terminal of the inverter to the capacitor or LC/RC noise filter with phase lead, otherwise, the internal components of the inverter may be damaged.
◆ When contactor is installed between the inverter and the motor, it is forbidden to switch on/off the contactor during the running of the inverter, otherwise, there will be large current flowing into the inverter, triggering the inverter protection action.
◆ Length of cable between the inverter and motor If the cable between the inverter and the motor is too long, the higher harmonic leakage current of the output end will produce by adverse impact on the inverter and the peripheral devices. It is suggested that when the motor cable is longer than 100m, output AC reactor be installed. Refer to the following table for the carrier frequency setting