Shenzhen Veikong Electric Co., Ltd.

Shenzhen Veikong Electric Co., Ltd.

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Variable Frequency Inverters /

IP20 IP21 Variable Frequency Inverters Controllers With New LED Models

Contact Now
Shenzhen Veikong Electric Co., Ltd.
Visit Website
City:shenzhen
Country/Region:china
Contact Person:MrTerry
Contact Now

IP20 IP21 Variable Frequency Inverters Controllers With New LED Models

Ask Latest Price
Video Channel
Brand Name :VEIKONG
Model Number :VFD500
Certification :CE IEC
Place of Origin :China
MOQ :22 pcs
Price :negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :15000 per/ month
Delivery Time :3-8 working days
Packaging Details :paper carton under 45kw, starting from 45kw wooden case for packing
Display models :New LED displays
Protection level :IP20/ IP21
Practical function :PC Tool software
Brand name :Veikong
Warranty :18 months
product name :variable frequency drive VFD
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IP20 IP21 Variable Frequency Inverters Controllers With New LED Models

Factory Variable Frequency Inverters Controllers With New Veikong LED Models

1. VFD500 with new LED disaply VFD functions and features
1) Optimized SVC algorithm, stable operation in power generation
2) Tension control and torque mode controlU

3) Comparator and logic unit/controllerSleeping functionVirtual DI functionProgrammable delay unit
4) Motor Auto-tune (static and dynamic)2 motor parameter groups

5) DC Injection braking

2. Veikong new LED features compared with old version comparison

1Old modelNew model
Physical pic IP20 IP21 Variable Frequency Inverters Controllers With New LED ModelsIP20 IP21 Variable Frequency Inverters Controllers With New LED Models
Comparison DescriptionThe button is small so it’s inconvenient to press, and the silicone button is easy to get stuck.The operation button is upgraded and the surface of finger pressing is enlarged, which is easy to press. The structure of the silicone button is upgraded to solve the problem of easy getting stuck.
2
Physical PictureIP20 IP21 Variable Frequency Inverters Controllers With New LED ModelsIP20 IP21 Variable Frequency Inverters Controllers With New LED Models
Comparison DescriptionThe upper and lower covers of the keyboard are matched with buckles. The gaps between the two covers are uneven. The buckles are not tight enough and easy to loosen. The buckles are exposed which affects the appearance. The upper and lower covers of the keyboard are fixed by screws at the bottom, which is very firm. And the matching position is hidden at the bottom to ensure the surface could be more beautiful.
3
Physical PictureIP20 IP21 Variable Frequency Inverters Controllers With New LED ModelsIP20 IP21 Variable Frequency Inverters Controllers With New LED Models
Comparison DescriptionThere is no guidance of the external keypad opening size at the bottom, and the opening size needs to check in the user manual, which is inefficient.After the upgrade, it adds an opening size diagram at the bottom when the keyboard needs to be drawn out, which can be viewed immediately without having to read the manual.
4
Physical PictureIP20 IP21 Variable Frequency Inverters Controllers With New LED ModelsIP20 IP21 Variable Frequency Inverters Controllers With New LED Models
Comparison DescriptionDifficult to remove the keyboard.After the upgrade, the keyboard is easy to remove


3. Veikong VFD500 series well applied in many different areas
IP20 IP21 Variable Frequency Inverters Controllers With New LED Models
IP20 IP21 Variable Frequency Inverters Controllers With New LED Models

4. Veikong product brochure and user manual download center
VEIKONG VFD500 high performance vector and torque ...
veikong catalog latest.pdf

5. Motor Wiring
◆ It is forbidden to short circuit or ground the inverter output terminal, otherwise the internal components of the inverter will be damaged.
◆ Avoid short circuit the output cables or with the inverter enclosure, otherwise there exists the danger of electric shock.
◆ It is forbidden to connect the output terminal of the inverter to the capacitor or LC/RC noise filter with phase lead, otherwise, the internal components of the inverter may be damaged.
◆ When contactor is installed between the inverter and the motor, it is forbidden to switch on/off the contactor during the running of the inverter, otherwise, there will be large current flowing into the inverter, triggering the inverter protection action.
◆ Length of cable between the inverter and motor If the cable between the inverter and the motor is too long, the higher harmonic leakage current of the output end will produce by adverse impact on the inverter and the peripheral devices. It is suggested that when the motor cable is longer than 100m, output AC reactor be installed. Refer to the following table for the carrier frequency setting




























Inquiry Cart 0