220V 5.5KW 7.5KW Solar Pump Inverter Single Phase Input Single Phase Output
VFD Single Phase Input Feature:
Eletrical Specification
220V | 380V | |
Max input DC voltage | 450V | 810V |
DC voltage range | 150~450VDC | 250~810VDC |
Recommended input mppt voltage | 305V | 530V |
MPPT efficiency | >99% | |
Rated output voltage | 1/3-phase 220VAC | 3-phase 380-480VAC |
Output frequency range | 50/60Hz | |
Max efficiency of the machine | 99% | |
Ambient temperature range | -10 °C~50 °C, derating if the temperature is above 40 °C | |
Cooling method | Air cooling |
Protection degree | IP20/IP21 |
Altitude | Below 1000m; above 1% for every additional 100m. |
Standard | CE/ROHS |
Product Model
Drive model | Max DC input current (A) | Rated output current (A) | Applicable water pump (kW) |
VFD500M-40T00075-PV | 4.2 | 2.5 | 0.75 |
VFD500M-40T00150-PV | 6.1 | 3.7 | 1.5 |
VFD500M-40T00220-PV | 7.1 | 5 | 2.2 |
VFD500M-40T00400-PV | 16.5 | 9.4 | 4 |
VFD500M-40T00550-PV | 23.9 | 13 | 5.5 |
VFD500M-40T00750-PV | 30.6 | 17 | 7.5 |
220V single phase or three phase level | |||
VFD500M-20T00075-PV | 6.7 | 4.5 | 0.75 |
VFD500M-20T00150-PV | 9.9 | 7 | 1.5 |
VFD500M-20T00220-PV | 14.1 | 11 | 2.2 |
VFD500M-20T00400-PV | 22.6 | 17 | 4 |
Product Details
FAQ:
1. How to use a float in the water tank to stop the pump if the tank is full?
Use float switch to short DI 1 and com.
2.1 How to set minimum frequency 25hz and maximum 50HZ?
Set P47.05=25HZ and 47.06 to some time and 47.07 to some time
3. 1 If pump is 60HZ frequency ,how to set max frequency?
Notice:If your motor rated frequency is 60HZ you should set P01.06=P01.08=P11.05=60HZ.