
Add to Cart
Submersible Solar Water Pump Inverter Single Phase VFD 0.75KW To 710KW
VEIKONG Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW
VEIKONG is professional manufacturer of solar pump inverter, variable frequency dirve, soft starter.
Electrical Specifications and Power degree
220V | 380V | |
Max input DC voltage | 450V | 810V |
DC voltage range | 150~450VDC | 300~810VDC |
Normal working DC voltage | 260V-400V | 400V-650V |
Recommended input mppt voltage | 330V | 550V |
MPPT efficiency | >99% | |
Rated output voltage | 1/3-phase 220VAC | 3-phase 380-480VAC |
Output frequency range | 50/60Hz | |
Max efficiency of the machine | 99% | |
Power range | 220v 0.75kw to 75kw, 380v 1.5kw-160kw | |
Cooling method | Air cooling | |
Protection degree | IP20/IP65 | |
Altitude | Below 1000m; above 1% for every additional 100m. | |
Standard | CE/ROHS |
Noted: We suggest solar panel power should be 1.3-1.4 times higher than solar pump power ,
And solar pump inverter power should be higher level than solar pump.
When solar pump distance to inverter higher than 100m,
It should be equipped with Output reactor or higher level power inverter.
For Solar panel,total VOC less than Maximum DC voltage of inverter and Solar panel vmp is recommend
530V for 380V pump and 305V for 220V pump.
VEIKONG VFD500-PV solar pump inverter Features:
Protection features
Mode Range
Drive model | Max DC input current (A) | Rated output current (A) | Applicable water pump (kW) |
VFD500M-40T00150-PV | 6.1 | 3.7 | 1.5 |
VFD500M-40T00220-PV | 7.1 | 5 | 2.2 |
VFD500M-40T00400-PV | 16.5 | 9.4 | 4 |
VFD500M-40T00550-PV | 23.9 | 13 | 5.5 |
VFD500M-40T00750-PV | 30.6 | 17 | 7.5 |
VFD500-40T00150-PV | 6.1 | 3.7 | 1.5 |
VFD500-40T00220-PV | 7.1 | 5 | 2.2 |
VFD500-40T00400-PV | 16.5 | 9.4 | 4 |
VFD500-40T00550-PV | 23.9 | 13 | 5.5 |
VFD500-40T00750-PV | 30.6 | 17 | 7.5 |
VFD50040T01100-PV | 39.2 | 25 | 11 |
VFD500-40T01500-PV | 49.0 | 32 | 15 |
VFD500-40T01850-PV | 57 | 37 | 18.5 |
VFD500-40T02200-PV | 69 | 45 | 22 |
VFD500-40T03000-PV | 91 | 60 | 30 |
VFD500-40T03700-PV | 114 | 75 | 37 |
VFD500-40T04500-PV | 146 | 90 | 45 |
VFD500-40T05500-PV | 190 | 112 | 55 |
VFD500-40T07500-PV | 237 | 152 | 75 |
VFD500-40T09000-PV | 273 | 176 | 90 |
VFD500-40T11000-PV | 319 | 210 | 110 |
VFD500-40T13200-PV | 389 | 253 | 132 |
220V single phase or three phase level | |||
VFD500-20T00075-PV | 6.7 | 4.5 | 0.75 |
VFD500-20T00150-PV | 9.9 | 7 | 1.5 |
VFD500-20T00220-PV | 14.1 | 10.6 | 2.2 |
VFD500-20T00400-PV | 22.6 | 17 | 4 |
VFD500M-20T00150-PV | 9.9 | 7 | 1.5 |
VFD500M-20T00220-PV | 14.1 | 10.6 | 2.2 |
For 220V single phase motor connection
1: Single phase asynchronous motor wiring method (without starting capacitor):
Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;
Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.
First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ
For 220V single phase motor connection
2: Single-phase asynchronous motor wiring method (with capacitor)
Notice1: First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=21 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ